Professional supply of infrared thermometer
3i series infrared thermometer
(-30 to 1200 ° C) (200 to 1800 ° C) (600 to 3000 ° C)
The 3i series is available in a variety of temperature ranges, aiming methods, and optical resolutions, and provides spectral response to meet industry-specific applications. These models provide the best performance for long-distance high-temperature targets, up to 3000 ° C. With 3i products, you have the following options: single laser aiming, dual laser aiming, cross laser aiming, and telescope aiming.
Features:
3i General Recommended Model
Temperature range: -30 ° C ~ 1200 ° C
Response wavelength: 8-14 microns
D: S: 75: 1 ~ 120: 1
Emissivity: 0.1 ~ 1.0, digital adjustable
Power supply: four AA alkaline batteries or 6-9VDC, 200 mA
3i high temperature type
temperature range:
1M temperature measurement range: 600 ° C ~ 3000 ° C
2M temperature measurement range: 200 ° C ~ 1800 ° C
Response wavelength: 1.0 micron (1M), 1.6 micron (2M)
Emissivity: 0.1 ~ 1.0, digital adjustable
Power supply: four AA alkaline batteries or 6-9VDC, 200 mA
Special for glass industry
Temperature measurement range: 150 ° C ~ 1800 ° C
Response wavelength: 5.0 microns
Emissivity: 0.10-1.0, digitally adjustable
Power supply: four AA alkaline batteries or 6-9VDC, 200 mA
Film plastic industry
Temperature range: 10 ° C ~ 800 ° C
Response wavelength: 7.9 microns
Emissivity: 0.10-1.0, digitally adjustable
Power supply: four AA alkaline batteries or 6-9VDC, 200 mA
Technical index:
model | LT | LR | 1M | 2M | P7 plastic type | G5 glass type | |
Sight | double/ cross laser /telescope | Single laser / telescope/ Bifunctional | Single laser / telescope | Single laser / telescope | Dual laser | telescope | |
measuring range | -30 ~ 1200 ℃ | 600 ~ 3000 ℃ | 200 ~ 1800 ℃ | 10 ~ 800 ℃ | 150 ~ 1800 ℃ | ||
Distance coefficient D: S | 75: 1 | 120: 1 | 105: 1 | 180: 1 | 90: 1 | 25: 1 | 50: 1 |
response wavelength | 8 ~ 14 microns | 1 micron | 1.6 microns | 7.9 microns | 5.0 microns | ||
response time | 700 ms | 550 ms | 700 ms | ||||
detector | Thermopile | silicon | InGaAs | Thermopile | |||
measuring Features | Real-time value, minimum value, maximum value, average value, difference value, data readjustment, high / low temperature alarm Data recording, memory 100 points, ambient temperature compensation | ||||||
measuring Accuracy | ≤ ± 1% of measured value (1M type: ± 0.5%) or ± 1 ℃, whichever is greater (at ambient temperature 23 ℃ ± 5 ℃) | ||||||
repeat Accuracy | ≤0.5% of measured value or ± 1 ℃, whichever is greater | ||||||
liquid crystal display | 1 ℃ unit, 4 digits LCD with backlight, 7 seconds hold | ||||||
Emissivity | 0.1 ~ 1.0 digital adjustable | ||||||
simulation Output | 1mV / ℃ | ||||||
digital Output | RS232 9600 baud, output interval can be adjusted between 1 ~ 9999 seconds | ||||||
power supply | Four AA alkaline batteries or 6 ~ 9VDC. 200mA | ||||||
jobs temperature | 0 ~ 50 ℃ | ||||||
Storage temperature | -20 ~ 50 ℃ (without battery) | ||||||
relatively temperature | 10 ~ 95% (non-condensing at 30 ℃) | ||||||
weight/ size | 794g / 208mm X 257mm X 71mm (laser type) 1000 g / 244 mm X 257 mm X 71 mm (telescope type) | ||||||
Option 1 | NIST inspection certificate (must be specified when ordering) | ||||||
Option 2 | IBM Compatible Digital Output Software: Datatemp® 2 Software / Printer / Voltage Adapter Cable / Brightness Filter for Analog Printing Computer |